Model: qVisc 4340 DX Autosampled Viscometer (New)

The Fluid Life Corporation is proud to introduce the new qVisc 4340 DX dual arm autosampled viscometer. Built around our line of successful autosampled and manual inject viscometers with over a decade long track record and extensively field tested in high volume production used oil analysis laboratories, the new qVisc 4340 DX raises the bar on high volume viscosity measurement. With a staggering improvement in throughput of over 2.5 times our previous system, the qVisc 4340 DX can deliver up to 205 viscosity measurements per hour. Designed to have lower maintenance needs and use less cleaning solvent, the qVisc 4340 DX is the ultimate solution for production laboratories in need of high throughput viscosity measurements.

For more information, please download our complete brochure as well as a comprehensive white paper on the unique benefits of our patented tube design.

(qVisc_4340DX_brochure.pdf)
(qvisctubewhitepaper.pdf)

Features

  • Autosampled
Totally automated, unattended viscosity determination at one or two temperatures from one sample.
  • High Throughput
Two baths, two temperatures, eight tubes, and two autosampler arms delivers up to 205 samples per hour for samples measured at one temperature and up to 100 samples per hour samples measured at two temperatures. See the throughput graphs on the page below for details. The autosampler can hold over 288 samples.
  • Wide Range
Covers the range for almost any lubricating fluid viscosity and temperature with no tube selection or splitting samples.
  • Convenient
Compact floor stand design requires no fume hoods or duct work. Solvent vapors do not escape.
  • Low Maintenance
Enhanced valve design, enlarged bore fast run 100C tubes, and fully automated glass cleaning, work together to keep the instrument soot and build up free. Roll out instrument platform and strategically placed doors and pop off panels allow easy access for maintenance.
  • Easy To Use
Advanced Windows based software controls the instrument and has flexible reporting options including managed daily log files, transfer to LIMS over serial or TCP/IP network links, save and restore sample information files, visually select sample locations, VI computations, and much more.
  • Frugal
As little as 12 ml of solvent is used to clean a sample used for a single temperature measurement and as little as 20 ml for a sample measured at two temperatures. Typical average usages are 16 ml for single temperature and 26 ml for two.
  • Accurate
Patented tube design verifies ASTM D445 method applies by measuring how Newtonian the samples are, and also rejects inaccurate measurements in ways no other instrument can (see our white paper for more information). High speed optical meniscus detection is immune to changes in fluid darkness.
  • Reliable
Advanced computer software automatically runs QC checks, and constantly checks the system for proper operation. At the first sign that a tube is not functioning correctly, or may be returning inaccurate results, the tube is automatically taken offline while functioning tubes remain working.
  • Safe
Smart controllers shut down if unable to maintain steady temperature. Separate over temperature detectors and bath level float sensors remove power if bath fluid too low or any other over temperature event occurs. At no time is solvent placed under pressure, all cleaning is done by simply drawing up solvent under vacuum.

qVisc 4340 DX Autosampled Viscometer
Sample Throughput Rates

Specifications:

Viscosity Tubes per Unit:
  Temperature #1 (typically 40°C): 4
  Temperature #2 (typically 100°C): 4
Sample Throughput:
  2 Temperature Operation: up to 100 / hr
  1 Temperature Operation: up to 205 / hr
Temperature Range:
  Min: Ambient + 10°C
  Max: 105°C
Sample Size:
  2 Temperature Operation: less than 4.5 ml
  1 Temperature Operation: less than 2.5 ml
Usable Viscosity Range:
  40°C: 2 - 1000 cSt
  100°C: 0.95 - 80 cSt
(Preheater recommended above 350 cSt at 40°C, 40 cSt at 100°C)
Repeatability*: less than 0.9% 19 times out of 20
Reproducibility*: less than 1.35% 19 times out of 20
Solvents Recommended: N-Heptane, Toluene
Solvent Usage:
  2 Temperature Operation: approx. 26 ml per sample
  1 Temperature Operation: approx. 16 ml per sample
Cleaning Cycle:
  Software controlled automatic
Viscosity Bath Fluid:
  Type: Silicone SIL50
  Quantity: 10 liters per bath
Power Requirement:
  Voltage/Freq: 120@60Hz or 240@50-60Hz
  Max Draw: 1800 Watts
Dimensions, approximate: 44" x 30" x 74"
  Width, Depth, Height (112 x 76 x 188 cm)
Shipping Weight, approximate: 198 lbs (90kg)

*As defined in ASTM D445

 

Consult your Fluid Life Regional Account Manager concerning any of the quality laboratory instruments manufactured and distributed by The Fluid Life Corporation.