myLab
-
Services
-
- Acid Number
- Analytical Ferrography
- Base Number: ASTM D2896 vs. D4739
- Crackle Test: Monitoring Water in Used Oil
- Demulsibility
- FTIR Direct Trend Methodology
- Fuel Distillation (ASTM D86)
- ISO Particle Count
- Karl Fischer Water Titration
- Optical Particle Classification (OPC)
- Remaining Useful Life Evaluation Routine (RULER)
- SEM-EDS Wear Debris Analysis
- Total Magnetic Iron (TMI)
- Varnish Potential
-
-
Sampling
-
- Coolant Sampling Procedures
- Grease Sampling Procedures
- Oil Sampling Basics (Short Course)
- Oil Sampling Procedures (Video)
- Oil Sampling Procedures: Good-Better-Best (PDF)
- Sample Collection Basics
- Sampling Oil Using a Drain Plug
- Sampling Oil Using a Pushbutton or KST-Series Valve
- Sampling Oil Using a Sample Pump
- Sampling Oil Using Thread-On Probe Style Valves
- Used Oil Filter Sampling
- Sampling from Filter Carts
-
-
Data Interpretation
-
- Analytical Ferrography Reporting
- Basic Testing Interpretation (PDF)
- Common Wear Mechanisms (PDF)
- DEF Specifications: ISO 22241
- Oil Cleanliness: ISO vs. NAS
- Potential Source of Spectrometry Metals (PDF)
- Reading the OA Report (PDF)
- Understanding ISO Particle Counts (PDF)
- Wear Metal Origins (PDF)
- Comparison: Wear Debris Analysis Technologies
- DEF Testing: Data interpretation
- Why Diesel Fuel Dilution is Bad for Your Engine
-
- Data Interpretation Process (Video)
- Data Interpretation: Compressors (Video)
- Data Interpretation: Diesel Engines (Video)
- Data Interpretation: Grease Analysis for Wind Turbines (VIDEO)
- Data Interpretation: Hydraulics (Video)
- Data Interpretation: Natural Gas Engines (Video)
- Data Interpretation: Oil Analysis for Wind Turbines (Video)
- Data Interpretation: Reducers (Video)
- Data Interpretation: Turbines (Video)
-
-
Whitepapers
-
Success Stories
-
FAQ
-
Release Notes
< All Topics
Print
Total Magnetic Iron (TMI)
PostedFebruary 1, 2022
UpdatedFebruary 1, 2022
ByFluid Life
Overview
Total Magnetic Iron (TMI) is a highly accurate test option designed to measure the degree of ferrous wear metal contamination in an oil sample. The TMI is not sensitive to particle size.
With routine sampling a TMI provides early detection of abnormal wear conditions and imminent equipment failure. It is an excellent screening tool that can be used as a trigger to the more advanced Analytical Ferrography or SEM. Total Magnetic Iron is an easy addition to any existing oil analysis program.
How it works
When used along with traditional spectrometry several evaluations can be made.
- If both the TMI and spectrometric values increase, it is likely that many small particles are being generated.
- If TMI increases and there is no change or a decrease in the spectrometric ferrous values (i.e. iron, nickel), this suggests large particles are being generated which indicates an abnormal level of wear.
Benefits
- An accurate triggering test for Analytical Ferrography or SEM.
- A valuable addition to your conventional sampling program.
- An excellent return on your oil analysis investment.
Applications
- Engines
- Gearboxes
- Final Drives
- Transmissions
- Industrial Gear Systems
- All other systems that have the potential to generate large ferrous particles.
Table of Contents